Copanga admin on June 28, 2019 Search Entries: Room Name (dropdown) Sales Area | Storefront Exterior | Restroom Alcove | Men’s Restroom | Women’s Restroom | Break Room | Janitor’s Closet | Egress Corridor | Electric Room | Offices/Fitting Rooms | Back Room | Basement | Mechanical Mezzanine | Roof | Rear Exterior Discipline Selection Electrical | Fire Alarm | HVAC | Lighting | Plumbing | Technology | Other Clear Room nameDiscipline SelectionSubject MarkNotes Rear ExteriorPlumbingGM-Main Rear ExteriorPlumbingGM-SubThis meter appears to serve a specific space more than halfway down the length of the building. There doesn?t appear to be a gas line running to our space. RoofElectricalAC-7Fused. RoofElectricalAC-6Fused. RoofElectricalAC-5Fused. RoofElectricalAC-4Fused. RoofElectricalAC-3Fused. RoofElectricalAC-2Fused. RoofElectricalAC-1Fused. RoofHVACAC-1Condensate line is broken. Piping under roof exists, but there is no sign it connects to the rooftop unit unless it is within the curb. No roof penetration.) RoofHVACAC-2Condensate line is broken. Piping under roof exists, but there is no sign it connects to the rooftop unit unless it is within the curb. No roof penetration. RoofHVACAC-3Condensate drain penetrates roof and goes down into space (back room). RoofHVACAC-4Condensate line is broken. Piping under roof exists, but there is no sign it connects to the rooftop unit unless it is within the curb. RoofHVACAC-5Condensate line is broken. Piping under roof exists, but there is no sign it connects to the rooftop unit unless it is within the curb. (No rooftop penetration.) RoofHVACEF-1Serves restrooms. RoofHVACEF-2Adjacent to AC-5. Centri Master Model: PV100E3 1/4 hp 115V Serves Janitor?s Closet. More than 10 feet away from rooftop unit intake. RoofHVACAC-6Condensate line is broken. Piping under roof exists, but there is no sign it connects to the rooftop unit unless it is within the curb. RoofHVACAC-7Condensate drain penetrates roof and goes down into space (back room). Mechanical MezzanineElectricalMSB BasementFire AlarmFor Main LeftDial reads nearly 150 psi. BasementFire AlarmFire Main RightMeter reads almost 140 psi BasementElectricalLB30A 3P breaker on the left. (1) 20A 3P breaker and (4) 20A 1P breakers on the right. Back RoomHVACAC-7Bottom of the supply air diffuser at 16?6?. Bottom of the return air duct at 17?8?. Back RoomHVACAC-6Bottom of the supply diffuser at 18?1?. Bottom of the return air duct at 19?3?. Back RoomFire AlarmFACP Room nameDiscipline SelectionSubject MarkNotes